Skip to product information

ATEN EC1000 Energy Box with Real-time Power Monitoring

SKU AB50870 Model# EC1000
ATEN EC1000 Energy Box with Real-time Power Monitoring(EC1000) - 1

ATEN EC1000 Energy Box with Real-time Power Monitoring

Description
SKU AB50870 Model# EC1000
• ATEN EC1000 NRGence Energy Box over IP Environment Monitoring via Opt Sensors
View full item details
Delivery

Australia
Standard Shipping 4-7 business days: AU $8.95*
Express Shipping 1-3 business days: AU $15*

International Shipping
New Zealand 9-12 business days: AU$21*

*During peak promotional periods, please allow additional time for your order dispatch.

Learn more

Returns

While we can’t offer a refund or replacement if you simply change your mind, we’re here to help if your item has a problem under Australian Consumer Law. You may be entitled to a refund or exchange if an item has a major problem. This is when the item:

  • has a problem that would have stopped someone from buying the item if they had known about it
  • is unsafe
  • is significantly different from the sample or description
  • doesn't do what we said it would, or what you asked for and can't be easily fixed


If the problem is not major, we will repair the item within a reasonable time. If it can’t be repaired in a reasonable time, we’ll offer a suitable resolution such as a refund or replacement. Please keep your proof of purchase — e.g. your receipt.

Read more

$442.95
Sale price  $442.95
Sold out
Awaiting stock
Payment plan Payment plan Payment plan
Payment plan
Payment plan Payment plan Payment plan
Payment plan
Bank Transfer

BANK TRANSFER (EFT)

Help icon

Need help? Ask our team

Email
Promotional banner
$442.95
Sale price  $442.95
Awaiting stock

Accepted payment methods

  • Visa
  • Mastercard
  • American Express
  • PayPal
  • UnionPay
  • Alipay
  • WeChat Pay
  • LatitudePay
Help icon

Need help? Ask our team

Email
Description
• ATEN EC1000 NRGence Energy Box over IP Environment Monitoring via Opt Sensors
View Full Details
Delivery

Australia
Standard Shipping 4-7 business days: AU $8.95*
Express Shipping 1-3 business days: AU $15*

International Shipping
New Zealand 9-12 business days: AU$21*

*During peak promotional periods, please allow additional time for your order dispatch.

Learn more

Returns

While we can’t offer a refund or replacement if you simply change your mind, we’re here to help if your item has a problem under Australian Consumer Law. You may be entitled to a refund or exchange if an item has a major problem. This is when the item:

  • has a problem that would have stopped someone from buying the item if they had known about it
  • is unsafe
  • is significantly different from the sample or description
  • doesn't do what we said it would, or what you asked for and can't be easily fixed


If the problem is not major, we will repair the item within a reasonable time. If it can’t be repaired in a reasonable time, we’ll offer a suitable resolution such as a refund or replacement. Please keep your proof of purchase — e.g. your receipt.

Read more

Frequently bought with

The EC1000 Energy Box is the latest evolution of NRGence? – ATEN's energy intelligence solutions. It is the intelligent, cost effective solution to monitor ATEN's Energy PDUs – to ensure safe and effective energy-saving power management.
The EC1000 Energy Box has four Energy Sensor ports to connect to four Energy PDU modules and four Environment Sensor ports for external sensors to monitor environmental conditions. Each environmental sensor can provide measured readings of temperature, humidity, and differential pressure from separate areas of a data room, giving a wide range of monitoring and protection you need.
The Energy Box allows power and environmental data to be monitored and displayed at the rack or remotely for easy viewing and maintenance. The Energy Box is a standalone unit with Over IP monitoring that is controlled by Web GUI or ATEN′s eco Sensors software.
The EC1000 Energy Box features real-time status, system logs, threshold alerts, and event notifications. The EC1000 logs power and environmental conditions according to customizable minimum/maximum thresholds set for electrical current, temperature, humidity, and differential pressure.
Remote monitoring offers secure access with 128bits SSL encryption, and customizable account policies for user management. Remote authentication supports RADIUS and additional management interfaces including HTTP, HTTPS, and SNMPv1&v2&v3 (Read, Write, Trap). Event notifications can be monitored via Syslog/SMTP/SNMP trap and audible alarms for real–time local and remote alerting.
When used in conjunction with ATEN′s Energy PDUs* and eco Sensors Energy Management Software*, the EC1000 allows you to conveniently upgrade your cabinet with remote energy management functionality to make your server room go green quickly and cost-effectively.
Operation
Space saving 1U rack mounting with front and rear mounting
4 RJ-45 Energy Sensor Ports to monitor four Energy PDU currents (0A to 32A per port)
4 RJ-11 Environment Sensor Ports to monitor temperature, humidity, and differential pressure*
Maximum Amperage Monitor 32A@100V~240V (Energy Box)
3 digit 7 segment front panel LED displays current/sensor/IP address information
Threshold monitoring for:
1.Current
2.Temperature*
3.Humidity*
4.Differential pressure*
Threshold alerting through:
1. Local: audible alarm and LED lights
2. Remote: SMTP/SNMP trap/Syslog
Management
Front panel LED indicators for current, temperature*, humidity*, differential pressure*, and IP address information at the Energy Box
Remote real-time current, temperature*, humidity*, and differential pressure* monitoring and management
Management through eco Sensors Energy Management Software or 3r party SNMP manager
Supports name assignment for individual Energy PDUs
Event Logging – 128 line event log
Syslog support
F/W upgradable
Remote Access
Remote management via TCP/IP using built in 10/100Mbps Ethernet port
Management via built in browser based GUI
Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping
Supports SNMP Manager V1, V2, V3
Security
Strong security features include password protection and advanced encryption technologies – utilizing 128 bit SSL
RADIUS authorization and authentication
* Requires external sensors

Energy PDU Connections 4
Port Selection Pushbutton
Connectors Energy Sensor 4 x RJ-45 Female
Environment Sensor 4 x RJ-11 Female
Power 1 x DC Jack
LAN 1 x RJ-45 Female
Switches Reset 1 x Semi-recessed Pushbutton
Selection 1 x Selection Pushbutton
LEDs PDU Status 4 (Orange)
Sensor Status 4 (Green)
Energy/Environment/IP 3 (Green)
Selection 1 digit 7-segment (Orange)
Current/Sensor/IP Address 3 digit 7-segment (Orange)
Power 1 (Blue)
LAN 10M/ 100Mbps 1 (Orange/Green)
Link 1 (Green)
Monitoring Range 100–240V; 50/60Hz; 0A to 32A (per port)
LED Display Resolution 0.1A
Precision: ±0.1A@0 ~ 1A, ±1% >1A
Power Consumption DC 5.3 V
Environment Operating Temp.

0-50°C

Storage Temp. -20-60°C
Humidity 0 - 80% RH, Non-condensing
Physical
Properties
Housing Metal
Weight 0.59 kg
Dimensions
( L x W x H )
20.00 x 7.59 x 4.20 cm


ATEN EC1000 NRGence Energy Box over IP