{"product_id":"apc-ap8953-rack-pdu-2g-switched-zerou-32a-230v-21-c13-3-c19-ab83355","title":"APC AP8953 Rack PDU 2G, Switched, ZeroU, 32A, 230V, (21) C13 \u0026 (3) C19","description":"\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eOVERVIEW:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eAgility\u003c\/strong\u003e\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eSingle input power source:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eWide range of input and output connections:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eRack-Mountable:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eMarketing Features\u003c\/strong\u003e\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eRemote Individual Outlet Control:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003ePower Delays:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eRemote Management Capabilities:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eAlarm Thresholds:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eLocal Current Monitoring Display:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eAvailability\u003c\/strong\u003e\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eFlash Upgradeable:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eIntegrates with StruxureWare Data Center Expert:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eAlarm Thresholds:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eLocal Current Monitoring Display:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003ePower Delays:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eLoad indicator LED:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eNetwork Management Capabilities:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.\u003cbr\u003e\n\u003cem\u003e\u003cstrong\u003eRemote Individual Outlet Control:\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\nRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eTECHNICAL SPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003cbr\u003e\nOverload Protection: Yes\u003cbr\u003e\nMaximum Total Current Draw: 32\u003cbr\u003e\nOutput Connections:\u003cbr\u003e\n(3) IEC 320 C19 (Battery Backup)\u003cbr\u003e\n(21) IEC 320 C13 (Battery Backup)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003cbr\u003e\nNominal Input Voltage: 200V , 208V , 230V\u003cbr\u003e\nInput frequency: 50\/60 Hz\u003cbr\u003e\nInput Connections: IEC 309 32A 2P+E\u003cbr\u003e\nCord Length: 3.05meters\u003cbr\u003e\nAcceptable Input Voltage: 220-240VAC\u003cbr\u003e\nNumber of Power Cords: 1\u003cbr\u003e\nMaximum Input Current: 32A\u003cbr\u003e\nMaximum Line Current: 32A\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003cbr\u003e\nMaximum Height: 1829mm , 182.9cm\u003cbr\u003e\nMaximum Width: 56mm , 5.6cm\u003cbr\u003e\nMaximum Depth: 46mm , 4.6cm\u003cbr\u003e\nNet Weight: 7.59kg\u003cbr\u003e\nShipping Weight: 9.95kg\u003cbr\u003e\nShipping Height: 2040mm , 204.0cm\u003cbr\u003e\nShipping Width: 165mm , 16.5cm\u003cbr\u003e\nShipping Depth: 124mm , 12.4cm\u003cbr\u003e\nColor: Black\u003cbr\u003e\nUnits per Pallet: 48.0\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003cbr\u003e\nOperating Environment: -5 - 45 °C\u003cbr\u003e\nOperating Relative Humidity: 5 - 95 %\u003cbr\u003e\nOperating Elevation: 0-3000meters\u003cbr\u003e\nStorage Temperature: -25 - 65 °C\u003cbr\u003e\nStorage Relative Humidity: 5 - 95 %\u003cbr\u003e\nStorage Elevation: 0-15000meters\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eConformance\u003c\/strong\u003e\u003cbr\u003e\nApprovals: EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE\u003cbr\u003e\nStandard warranty: 2 years repair or replace\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana,geneva,sans-serif\"\u003e\u003cstrong\u003eSustainable Offer Status\u003c\/strong\u003e\u003cbr\u003e\nRoHS: Compliant\u003cbr\u003e\nREACH: Contains No SVHCs\u003cbr\u003e\nBattery Directive: Compliant\u003cbr\u003e\nBattery Notes: ts_Battery_Notes\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":47994676609155,"sku":"AB83355","price":2351.95,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/6633\/7923\/files\/AB83355.jpg?v=1787795214","url":"https:\/\/www.mwave.com.au\/products\/apc-ap8953-rack-pdu-2g-switched-zerou-32a-230v-21-c13-3-c19-ab83355","provider":"Mwave","version":"1.0","type":"link"}